Earthquake Engineering
Since PROTA Engineering is the first earthquake
engineering company of Turkey, it has a broad
range of expertise in this field. It specializes
in the design of buildings and large structures,
seismic capacity assessment of structures,
repair and strengthening of damaged buildings
and software development for structural finite
element analysis, design and detailing.
PROTA has completed several projects funded
by the World Bank, European Investment Bank,
Eurepoean Commision, Europaid as well as seismic
risk reduction projects funded by several Turkish
ministries including Ministry of Public Works
and Settlement, Ministry of Education, Ministry
of Culture, Ministry of Health, Ministry of
Defence, Ministry of Interior, etc.
Besides, after 1992 Erzincan, 1995 Dinar,
1998 Adana / Ceyhan, 1999 Marmara, 2002 Afyon
and 2003 Bingöl earthquakes PROTA has
completed about twelve (12.0) million square
metres of
floor space in total of both earthquake risk
mitigation projects as structural performance
assessments, retrofit designs and technical
consultancy during constructions and post-earthquake
damage assessment, retrofitting and renovation
designs. PROTA’s specialised field inspectors
and two mobile field laboratories equipped
with damage
assessment equipment s are capable of accurately
identifying as-built structural conditions
and material properties to provide reliable
information for damage assessment and design
of retrofit measures.
PROTA Engineering has implemented many researches,
engineering services, construction supervision
works and technical consultancy services in
structural and earthquake engineering fields.

|
Republic Of Turkey – Ministry of Defense,
After Erzincan, 1992 earthquake, seismic
evaluation and retrofitting of the 3rd army headquarter
buildings, damage assesment, seismic evaluation,
retrofitting project and details, consultancy
and site supervision of 35 different type of
buildings. Total closed area: 75,000 sqm.

|
Middle
East Technical University and Earthquake Engineering
Research Institute-Ministry of Resettlement,
After Afyon-Dinar, 1995 earthquake, seismic
evaluation and retrofitting of the private residential
buildings,
damage assesment, in-situ drawings, seismic evaluation,
retrofitting project and details, consultancy
and site supervision of 40 different type of
multi-filoor residential buildings. Total closed
area: 39,692 sqm.
 
|
Gazi
University and Ministry of Resettlement,
After 1998, Adana earthquake, seismic
evaluation and retrofitting of the private residential
and
office buildings in Adana – Seyhan / Turkey,
damage assesment, in-situ drawings, dynamic and
static analysis, seismic evaluation, retrofitting
project and details, consultancy and site supervision
of 48 different type of multi-storey private
buildings. Total closed area: 48,772 sqm.
 
|
METU,
Earthquake Engineering Research Center and Ministry
of Resettlement, After 1998,
Adana earthquake, seismic evaluation and retrofitting
of the private residential and office buildings
in Adana – Ceyhan / Turkey, damage assesment,
in-situ drawings, dynamic and static analysis,
seismic evaluation, retrofitting project and
details, consultancy and site supervision of
113 different type of multi-storey private buildings.
Total closed area: 208,350 sqm.
 
|
Municipality
of Ceyhan, After
1998, Adana earthquake, seismic evaluation
and retrofitting
of the cooperative buildings in Adana – Ceyhan
/ Turkey, damage assesment, soil investigation,
in-situ drawings, dynamic and static analysis,
seismic evaluation, retrofitting project and
details, consultancy and site supervision of
160 different type of multi-storey residential
and cooperative buildings under construction.
Total closed area: 310,000 sqm.
 
|
University
of Gazi, Turkish
Postal Administration, After 1999, Marmara
earthquake, seismic evaluation
and retrofitting of the post office buildings
in earthquake region, damage assesment,
in-situ drawings, seismic evaluation, geological
and
soil investigation, retrofitting project and
details and consultancy of 19 different type
of Post office buildings. Total closed area:
23,253 sqm.
 
|
METU,
Earthquake Engineering Research Center,
TÜPRAŞ İzmit Petroleum Rafinery,
after 1999 Marmara earthquake, seismic vulnerability,
evaluation
and retrofitting of the refinery office, residential
and industrial buildings soil investigation,
geotechnical review, damage assesment, in-situ
drawings, seismic evaluation, retrofitting project
and details, consultancy and site supervision
of 54 different type of residential and industrial
buildings in Kocaeli / Turkey. Total closed area:
61,000 sqm.
 
|
University of Gazi, Turkish
Electricity Authority, After 1999, Marmara
earthquake, seismic evaluation
and retrofitting of the transformer and central
operation buildings in earthquake region, damage
assesment, in-situ drawings, seismic evaluation,
geological and soil investigation, retrofitting
project and details and consultancy of 12 different
type of buildings Total closed area: 16,119
sqm.
 
|
Emek
Construction and Management Co., seismic
evaluation and retrofitting project and detailing
of the Historical Çelik Palas Hotel buildings,
Bursa, damage assesment, seismic and
capacity evaluation, soil investigation, retrofitting
projects, site supervision and consultancy services
of the 3 blocks historical building. Total closed
area: 15, 020 sqm.
 
|
Emek
Construction and Management Co., seismic
evaluation and retrofitting project and detailing
of the New Çelik Palas Hotel buildings, Bursa,
seismic and capacity evaluation, soil investigation,
geotechnical review, retrofitting projects, site
supervision and consultancy services of the 11
blocks hotel and convention center buildings.
Total closed area: 89,000 sqm.
 
|
Turkish Retirement Administration, Seismic
evaluation and retrofitting project and detailing
of Bursa Santral Garaj buildings, damage assesment,
soil investigation, geotechnical review, seismic
and capacity evaluation, retrofitting projects
and consultancy services of the central intercity
terminal buildings. Total closed area: 5,000
sqm.
 
|
Republic of Turkey, University of Ankara,
Assessment and retrofitting of Ilgaz
rehabilitation Center, damage assesment, seismic performance
evaluation, retrofitting projects, quantity estimation
and consultancy services of office building in
Kastamonu. Total area : 8,533 sqm.
 
|
Emek Construction and Management Co., seismic
evaluation and retrofitting project and detailing
of the Efes Hotel, İzmir, damage assessment,
seismic and capacity evaluation, soil investigation,
geotechnical review, retrofitting projects, site
supervision and consultancy services of the 12
blocks of hotel and convention center buildings.
Total closed area : 80,019 sqm.
 
|
BAŞTAŞ Cement Industry Co., seismic
evaluation and retrofitting of the cement and
klinker silos,
The soil and geotechnical investigation, dynamic
structural finite element analysis, damage assessment
and retrofitting projects of the in-situ concrete
35 m high silos, in Ankara.
 
|
Republic Of Turkey – Ministry of Defense, Seismic
evaluation and retrofitting of the Naval Forces
Headquarter buildings, damage assesment, retrofitting
project and details and consultancy services of
Headquarter buildings. Total closed area : 26,900
sqm.
 
|
MESA Construction Co., seismic evaluation
and retrofitting of the underground garage building,
damage assesment, retrofitting project and details
and consultancy services of 4 storey underground
garage building. Total closed area : 14,000 sqm.
 
|
Koleksiyon Furniture Industry Co., seismic
evaluation and retrofitting project of the furniture
factory
buildings, the assessment and retrofitting projects
of precast concrete and steel factory buildings
and consultancy services in Tekirdağ / Turkey.
Total closed area : 14,000 sqm.
 
|
Emek Construction and Management Co., seismic
evaluation and retrofitting project and detailing
of the Hilton Hotel, İstanbul, damage assessment,
seismic and capacity evaluation, soil investigation,
geotechnical review, retrofitting projects, site
supervision and consultancy services of the 11
blocks of hotel and convention center . Total closed
area : 79,080 sqm.
 
|
Türkiye İş Bankası A.Ş., seismic vulnerability
and retrofitting project and detailing of the branch
office and residential buildings, damage assesment,
Field surveys, earthquake vulnerability assessment,
data collection, geological and geotechnical investigations
and reporting, material testing, structural analysis
and engineering services, retrofitting project
and detailing, architectural on site drawings,
of 172 banking branch offices and residential buildings
in Marmara and Aegean Regions of Turkey. Total
closed area : 220,000 sqm.
 
|
Ministry of Culture, Seismic evaluation,
performance analysis, retrofitting project and
detailing of
Adana Ağca Mosque, damage assessment, In-situ drawings,
seismic evaluation, retrofitting project, details,
technical supervision and consultancy services
of the oldest Mosque in Adana.
 
|
Turkish Tele -Communication Authority, seismic
evaluation and retrofitting project and detailing
of the central and office buildings, damage assesment,
soil and geotechnical investigations, seismic and
capacity evaluation, retrofitting projects and
consultancy services of 8 office buildings in Istanbul.
Total closed area : 20,100 sqm.
 
|
TUBITAK, Turkey Scientific and Technical Research
Authority and METU Civil Engineering Department,
Vulnerability Assessment of Existing Buildings.
A project based on evaluation of field evidence
toward development of alternative methodologies
for seismic vulnerability assessment of 477 undamaged
and damaged buildings in Düzce / Turkey. Total
closed area : Apprx. 700,000 sqm.
 
|
TÜPRAŞ Kırıkkale Petroleum Refinery, Seismic
evaluation and retrofitting project and detailing
of the isomerisation, hydrocracking and process
units of the refinery, damage assesment, in-situ
drawings, seismic evaluation, retrofitting project
and details, consultancy and site supervision of
different type of industrial buildings in Kırıkkale.
 
|
TUBITAK, Turkey Scientific and Technical Research
Authority, Assessment and retrofitting
of Marmara Research Center, tecnology park first
building,
damage assesment, seismic and capacity evaluation,
retrofitting projects and consultancy services
of scientific research building, Gebze/Istanbul.
Total closed area: 3,000 sqm.
 
|
SEKA A.Ş., Cellulose and Paper Industry, After
2002, Afyon earthquake, seismic evaluation and
retrofitting of the residential building, Damage
assesment, seismic performance evaluation, retrofitting
projects, quantity estimation and consultancy services
of residential building in Afyon. Total closed
area: 1,593 sqm.
 
|
TÜPRAŞ Aliağa Petroleum Refinery, Seismic
evaluation and retrofitting project and detailing
of the three
R/C industrial chimneys, damage assesment, soil
and geotechnical investigations, in-situ drawings,
seismic evaluation, retrofitting project and details,
consultancy and site supervision of different type
of residential buildings and three different height
( 60-89-107m ) industrial reinforced concrete chimneys
in İzmir. Total closed area: 35,000 sqm.
 
|
Ministry of Culture, performance analysis,
strenghtening and retrofitting project and detailing
of Perge
Stadion, restoration, damage assessment, In-situ
drawings, seismic evaluation, retrofitting project,
details, technical supervision and consultancy
services of the stone wall bearing ancient stadion
in Perge / Antalya.
 
|
Bursa Metropolitan Municipality, The
assessment and retrofitting project of 4 buildings
of fire
department, damage assesment, soil and geotechnical
investigations, seismic performance evaluation,
retrofitting projects, quantity estimation and
consultancy services of office buildings in Bursa.
Total closed area: 5,450 sqm.
 
|
Ministry of Culture, performance analysis,
strenghtening and retrofitting project and detailing
of Sofular
Region in Tarsus, damage assessment, In-situ drawings,
seismic evaluation, retrofitting project, details,
technical supervision and consultancy services
of the wall bearing and wooden structured 15 houses
in ancient Sofular zone in Tarsus / Mersin.
 
|
Istanbul
Technical University, Republic of Turkey, Ministry
of Finance, After 2002, Afyon
earthquake, seismic evaluation and retrofitting
of Afyon Tax
Building, damage assesment, seismic performance
evaluation, retrofitting projects, quantity estimation
and consultancy services of the office building
in Afyon. Total closed area: 18,000 sqm.
 
|
Republic
of Turkey, Central Bank, Seismic
evaluation, performance analysis, retrofitting
project and
detailing of the central bank buildings,
in-situ drawings, seismic evaluation, retrofitting
project
and details and consultancy services of different
type of 21 wall bearing, R/C and steel branch office
buildings in Antalya, Erzurum, Adana, Diyarbakır,
Eskişehir, İzmir, Samsun and İskenderun. Total
closed area: 64,703 sqm.
 
|
Oyak-Renault
Car Factory, Seismic evaluation,
performance analysis, retrofitting project and
detailing of the industrial and administrative
buildings of factory, damage assesment,
in-situ drawings, geotechnical review, seismic
evaluation,
retrofitting project and details, consultancy
and site supervision of different type of 3 office
and industrial steel, R/C and prefabricated buildings
in Bursa. Total closed area: 32,255 sqm.
 
|
TUSSIDE,
Turkish Industry Administrative and education
Authority, Seismic evaluation,
performance analysis, retrofitting project administrative
buildings,
in-situ drawings, seismic evaluation, retrofitting
project and details, consultancy and site supervision
of different type of 7office and R/C buildings
in Gebze, Istanbul. Total closed area: 9,000
sqm.
 
|
Republic
of Turkey, Ministry of Defence, Seismic
evaluation, performance analysis, retrofitting
project and detailing of the naval base buildings,
soil investigation, damage assesment, in-situ
drawings, seismic evaluation, retrofitting project
and details
and consultancy services of different type of
R/C and steel office and administrative buildings
in
Istanbul. Total closed area: 60,000 sqm.
 
|
METU,
Earthquake Engineering Research Center, BOTAŞ,
Crude Oil Pipelines Administration, Seismic
evaluation, performance analysis, retrofitting
project and detailing of the administrative buildings,
soil investigation, In-situ drawings, seismic
evaluation, retrofitting project and details
and consultancy
services of different type of 24 wall bearing,
R/C office and residential buildings in Ankara,
Bursa, İstanbul, Tekirdağ and Kırklareli. Total
closed area: 45,852 sqm.
 
|
Oyak-Renault
Car Factory, Seismic evaluation,
performance analysis, retrofitting project and
detailing of the industrial storage buildings,
damage assesment, in-situ drawings, seismic evaluation,
retrofitting project and details, consultancy
and site supervision of steel and prefabricated
industrial
storage building in Bursa. Total closed area:
26,000 sqm.
 
|
Ministry of Culture, performance analysis,
strenghtening and retrofitting project and detailing
of Hellenistic
Towers in Perge antique site, damage assessment,
In-situ drawings, seismic evaluation, retrofitting
project, details, technical supervision and consultancy
services of the stone wall bearing ancient towers
in Perge / Antalya.
 
|
Ministry
of National Education, Seismic
evaluation, performance analysis, retrofitting
project and
detailing of the Pension primary schools,
damage assessment, soil investigation and geotechnical
report, In-situ drawings, seismic evaluation,
retrofitting
project and details and consultancy services
of different type of 34 wall bearing, R/C school
and
pension buildings in Bingöl, İzmir, Bursa, Balıkesir
and Çanakkale. Total closed area: 285,000 sqm.
 
|
Ministry
of Labor, Seismic evaluation,
performance analysis, retrofitting project
and detailing of
the SSK Sopalı Hospital, damage assessment,
soil investigation and geotechnical report, In-situ
drawings, seismic evaluation, retrofitting project,
details, technical supervision and consultancy
services of different type of 17 blocks of Hospital
buildings in Kocaeli. Total closed area: 40,000
sqm.
 
|
LESSLOSS: Risk Mitigation for Earthquakes
and Landslides (Integrated Project) The LESSLOSS project
will have a permanent effect in reshaping the way
earthquake and landslide risk mitigation research
is carried out in Europe, creating bridges between
different fields of knowledge and the coordinated
remote use of facilities, resources and data, in
view of the technology transfer to the stakeholders
for effective risk reduction. A European research
area able to compete, in particular, with US and
Japanese centers in all fields related to earthquake
and landslide risk mitigation will result and may
progressively lead to the creation of permanent,
geographically distributed centers.
 
|
Turkey Marmara Emergency Reconstruction Project
(Loan Number: 4517-TU)
Consultancy Services for the Feasibility Studies
for Retrofitting of Selected Residential Buildings
in Istanbul
With BECA International - This project,
funded by a World Bank loan as part of the
Marmara Earthquake
Emergency Reconstruction Project, has undertaken
the seismic assessment of 369 apartment buildings
in the Municipality of Bakırköy, İstanbul.
The building materials have been sampled and
each building
measured so that it can be analysed to determine
its performance in a M 7.2 scenario event
some 12 km away. Retrofit solutions have been
developed,
designed and costed for each building, social
impact analyses, the cost-benefit ascertained,
and the
residents have been consulted as to the suitability/acceptability
of the retrofit scheme proposed. This is
an innovative project internationally which is
likely
to be replicated
by cities worldwide facing a similar risk
to İstanbul. Total closed area: 556,000 sqm.
 
|
Ministry of National Education, Consultancy
and Site Supervision Services for 54 School Buildings - retrofitting project evaluation, site supervision
and consultancy services of different type of 54
wall bearing, R/C school and pension buildings
in Bingöl, Siirt, Van, Muş, Hakkari, and Bitlis.
Total closed area: 233,000 sqm.
 
|
Kurtalan Cement Factory - Seismic evaluation
and retrofitting project and detailing of the production
and administrative buildings, geological investigations,
material testing, damage assesment, in-situ drawings,
seismic evaluation, retrofitting project and details,
construction supervision and consultancy of different
type of industrial buildings in Siirt-Kurtalan.
Total closed area: 44,500 sqm.
 
|
|
|
|